Dry-build underfloor heating · LindnerNORIT-TE 30 Therm GF underfloor heating element
A 30 mm gypsum fibre screed element with a click joint. It is part of the NORIT underfloor heating system: it distributes the load, and the fixed guide holds the NORIT heating pipe in place, in a variable laying pattern.
- 30 mm
- Pipe 12 mm
- Click joint
- Fire class A1
Not in the JUPITER Shop. Ask us about the options for your project.
What is NORIT-TE 30 Therm GF suitable for?
- Laid with a click joint, without screws.
- The fixed guide ensures safe and quick installation of the heating pipe.
- Extremely high fitting accuracy of the elements.
- Wet rooms up to water exposure class W1-I (W0-I and W1-I).
- Board material tested and recommended for healthy building (building biology).
Installation height from 23 mm. At least 3 mm of NORIT-Filler Universal goes over the elements. After approx. 24 hours the floor is ready for the floor finish. With a suitable heat pump you can also cool.
Technical data
| Versions | GF-U and GF-E |
|---|---|
| Effective size | 1200 × 600 mm |
| Thickness | 30 mm |
| Weight | approx. 24 kg (GF-U) and approx. 27 kg (GF-E) per element |
| Density | approx. 1,250 kg/m³ |
| Heating pipe | 12 mm |
| Standard centre-to-centre spacing | 120 mm |
| Joint | Click joint, without screws |
| Fire class | A1, non-combustible (EN 13501-1) |
| Product standard | EN 14190 |
| Wet rooms | Water exposure class W0-I and W1-I |
| Packaging | 40 elements per pallet (GF-U approx. 975 kg, GF-E approx. 1,100 kg) |
Source: Lindner product data sheet NORIT-TE 30 Therm GF (version 1.0, German) and the product page. Pipe diameter as stated by JUPITER Benelux.
Two elements


Installation
Tools: hand-held circular saw with guide rail for straight cuts, jigsaw for curves and small cut-outs.
- 1Let the elements acclimatise on site for 2 days and fit edge insulation along all walls: PE foam, stone wool or an alternative, depending on the requirements.
- 2Lay the elements according to the laying plan and join them with the click joint, without screws.
- 3Press the NORIT heating pipe (12 mm) into the milled guide.
- 4Apply NORIT-Filler Universal, at least 3 mm over the elements.
- 5After approx. 24 hours you can apply the floor finish, according to the installation guidelines and in line with the wishes and requirements of the floor finish supplier.
The ratio between universal (GF-U) and supplementary elements (GF-E) depends on the pipe layout. Send us the floor plan; we will work it out for you.
Ask for adviceDownloads
- Product data sheet NORIT-TE 30 Therm GFPDF · German · Lindner
Not sure about the build-up?
About the subfloor, wet rooms or underfloor heating: JUPITER Benelux is happy to advise. Weekdays 08:00–17:00 (CET).